LOI

Click on the material to see more complete information about its chemical composition.
Element CCRMP
Material
Concen-
tration
Units Classification*
LOI SY-4 4.56 % Certified
LOI TDB-1 0.3 % Provisional
LOI SCH-1 2.94 % Provisional
LOI WPR-1 10.2 % Provisional
LOI (1000°C) STSD-4 11.6 % Provisional
LOI (1000°C) LKSD-3 13.4 % Provisional
LOI (1000°C) LKSD-2 13.6 % Provisional
Loss on ignition CCU-1d 19.51 % Provisional
LOI (1000°C) STSD-3 23.6 % Provisional
LOI (1000°C) LKSD-1 29.9 % Provisional
LOI (1000°C) STSD-1 31.6 % Provisional
LOI (1000°C) LKSD-4 43.6 % Provisional
LOI (1000°C) TILL-3 4.6 % Provisional
LOI (1000°C) TILL-4 5.7 % Provisional
LOI (1000°C) TILL-1 7.3 % Provisional
LOI (1000°C) TILL-2 8.1 % Provisional
LOI (500°C) TILL-3 3.6 % Provisional
LOI (500°C) TILL-4 4.4 % Provisional
LOI (500°C) TILL-1 6.3 % Provisional
LOI (500°C) TILL-2 6.8 % Provisional
LOI (500°C) LKSD-3 11.8 % Provisional
LOI (500°C) LKSD-2 12.3 % Provisional
LOI (500°C) LKSD-1 23.5 % Provisional
LOI (500°C) LKSD-4 40.8 % Provisional
LOI (500°C) STSD-4 10.2 % Provisional
LOI (500°C) STSD-3 21.6 % Provisional
LOI (500°C) STSD-1 29.7 % Provisional
LOI (110°C, 24hres) BL-2 0.24 % Informational
LOI (110°C, 24hres) BL-3 0.25 % Informational
LOI (950oC) CD-1 4.0 % Informational
LOI BH-1 0.9 % Informational
LOI CH-4 0.9 % Informational
LOI CT-1 0.9 % Informational
LOI UMT-1 1.8 % Informational
LOI TLG-1 2.2 % Informational
LOI NBM-1 3.45 % Informational
LOI WGB-1 3.6-4.0 % Informational
LOI KZK-1 4.26 % Informational
LOI BL-4a 4.44 % Informational
LOI HV-2 4.72 % Informational
LOI BL-2a 5.16 % Informational
LOI MA-2c 7.55 % Informational
LOI SU-1b 8 % Informational
LOI GTS-2 9.3 % Informational
LOI MA-3a 10 % Informational
LOI  RTS-3a 10.6 % Informational
LOI RL-1 10.2 % Informational
LOI** WMS-1a 11 % Informational
LOI DS-1 13 % Informational
LOI CCU-1c 16.4 % Informational
LOI OKA-1 31.9 % Informational
LOI (1000°C) MA-1b 7.9 % Informational
LOI (900°C) DL-1a 1.43 % Informational

** Loss on ignition at 1000 – 1050°C

*Classification of the results by level of agreement

All concentration values are derived from an interlaboratory measurement program. Samples are sent to many laboratories, typically twenty to forty, and the results are analyzed statistically to determine the mean and other statistical parameters.

Certified: The value is calculated from a minimum of 10 sets of data that fulfill specific statistical criteria regarding agreement.

Provisional: The value is calculated from 8 or 9 sets of data that fulfill specific statistical criteria regarding agreement; or alternatively, more than 9 sets of data that do not fulfill the specific statistical criteria required for certification.

Informational: The value is calculated from 7 or fewer sets of data.

Note: Because of different digestion methods used, a single material may show different concentrations for a specific element. Details about methods are provided on the certificate and in the report.